Load acting on a buried pipeline (Marston formula)

ÀÛ¼ºÀÚ Uploader : ¾îÁ¦Ã³·³ ÀÛ¼ºÀÏ Upload Date: 2018-08-24º¯°æÀÏ Update Date: 2018-08-24Á¶È¸¼ö View : 400

Load acting on a buried pipeline (Marston formula)

¡Ý Cover depth (height from the top of pipeline to the ground surface level) = 1m in principle

¡Ý Load acting on pipeline

W = C©û* ¥ã * B©÷ (Marston formula)

where,
W : load on pipeline(ton/m)
C©û: coefficient depending on the depth and properties of cover material
¥ã : density of cover material (ton/§©)
B :  width (m) = 3d/2 + 0.3
D : outer diameter of pipe (m)
d : inner diameter of pipe (m)


*** Âü°í¹®Çå[References] ***

W = C©û* ¥ã * (3/2 * d + 0.3)^(2)
ÀÛ¼ºÀÚÀÇ ¼ö½Ä±×¸²ÀÌ ¾ø½À´Ï´Ù. No picture for this formula
º¯¼ö¸í Variable º¯¼ö°ª Value º¯ ¼ö ¼³ ¸í Description of the variable